MGDW Series - High and Low Temperature Chambers (Standard)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Humidity)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)
Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;
MGDW Series - High and Low Temperature Chambers (Double layer standard)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: 20℃~150℃; -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.
MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)
Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;