바로 상담
왕우미
영업 관리자 - 왕우미
왕우미
영업 관리자 - 왕우미
  • 전화 번호
    01081386313
    전화하기
  • QR 코드를 찍고 WeChat 추가
    w1713361168
    WeChat
  • QR 코드를 찍고 kakao 추가
    01081386313
    kakao
  • 이메일
    wangyuwei@neware.com.cn
    이메일 발송
왕우미
영업 관리자 - 왕우미
  • 전화 번호
    01081386313
    전화하기
  • QR 코드를 찍고 WeChat 추가
    w1713361168
    WeChat
  • QR 코드를 찍고 kakaokao 추가
    01081386313
    kakao
  • 이메일
    wangyuwei@neware.com.cn
    이메일 발송
지역 또는 언어 선택
Laptop Battery Testing
CE-5008-24V10A-SMB
  • Size of Each Unit (W*D*H)(mm)
    606*800*1800(mm)
  • Weight
    200kg;
  • AC Input
    AC 220V +10% / -20%, 50Hz;
  • Input Impedance

    Main Channel

    ≥1MΩ


    Auxiliary Channel

    ≥400kΩ

  • Input Active Power
    8CH(5008):500W;80CH(5080):5000W
  • Resolution
    AD:16bit;DA:16bit
  • Noise
    ≤80dB
  • Voltage and Current Sampling
    Four Wire Connection
  • Types of Power Devices
    MOSFET
  • Wiring Diagram of Input Power Supply
  • Voltage

    Range:(0.3V+0.05Ω/m*Length (m)*Current (A)+0.05Ω*Current (A))~5V;(e.g. Testing Line Length: 2m,Current: 2A,Voltage Range: 0.6V~5V);

    Testing/ Output Accuracy:± 0.02% of FS;

    Resolution:16bit (0.08mV);

    Stability:±0.25mV;

  • Current

    Independent 3-Range: 15mA; 300mA; 6000mA;

    Resolution:16bit (0.1mA);

    Testing/ Output Accuracy:±0.04% of FS;

    Stability: ±0.5mA @ 6000mA Range;

  • Power

    Single Channel Maximum Output Power: 30W;

  • Auxiliary Voltage

    Range: 0~5V;

    Resolution: 16bit(0.08mV);

    Accuracy: ±2.5mV;

  • Auxiliary Temperature

    Range:-40℃~+85℃;

    Resolution:0.1℃;

    Accuracy:±(0.5 + 0.01 * |Th - Tc|)℃  Th - Testing Spot Temperature; Tc - Instrument Spot Temperature;

  • Charge/ Discharge

    Charging& Discharging Mode: :Constant Current Charging / Constant Current/ Constant Voltage Charging / Resting / Constant Current Discharging / Constant Power Discharging / Constant Resistance Discharging / Constant Voltage Discharging


    Independent Internal Resistance Testing Step;


    Cut-off Conditions: Voltage, Current, Relative Time, Capacity, -ΔV;

  • Protect


    Software Protection

    Power down Data Protection;

    Function of Offline Test;

    The safety protection conditions can be set, and the setting specs include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit and delay time.



    Hardware Protection

    Hardware Anti-Reverse Connection Protection;

    Channel Over-Current Fusing;

  • Channels per Cabinet
    80
  • Step Setting Mode
    Sheet Editing
  • Data Record

    Data Recording Conditions

    Times △T:10ms~60000s;

    Voltage △U:0.5mV~5000mV;

    Current △I:1mA~6000mA;


    Local Data Record Capacity

    1GB/CH;

  • Database
    MySQL
  • Data Output Mode
    Excel, Txt
  • Curve Type

    Drawing Customized, 4 Y-Axes

  • Protection Level
    IP20;
  • Temperature

    Working Temperature Range: 25±5℃ (Accuracy Assurance), 25±20℃ (Extreme Working Temperature);

    Storage Temperature Range: 0~50℃;

    Temperature Drift: 50ppm;

  • Humidity

    Relative Humidity Range of Working Environment: ≤70% RH (There is no condensation of moisture.)

    Relative Humidity Range of Storage Environment: ≤80% RH (There is no condensation of moisture.)

Neware and Cookies
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies.Read our private policy